Technical Data
Volume capacity per kg. 48 in3 / 781 cc
Mixed density 0.044 lbs per in3 / 1.28 gm per cc
Coverage rate per kg.
@ 6-7 mils.
50-55 ft2 / 5 m2
Shelf life Indefinite
Volume solids 100%
Mixing ratio Base Activator
By volume 5.0 2
By weight 3.8 1

Cure Times
Ambient
Temperature
Working
Life
Touch
Dry
Maximum
Overcoating
Full
Cure
41°F 5°C 110 min 55 hrs 96 hrs 10 days
59°F 15°C 90 min 24 hrs 48 hrs 6 days
77°F 25°C 70 min 16 hrs 24 hrs 4 days
86°F 30°C 55 min 8 hrs 16 hrs 3 days

Physical Properties
  Typical Values

Test Method

Tensile Shear Adhesion
Steel 3700 psi 259 kg/cm2 ASTM D-1002
Aluminum 2700 psi 189 kg/cm2 ASTM D-1002
Copper    3000 psi 210 kg/cm2 ASTM D-1002
Stainless steel    3500 psi 245 kg/cm2 ASTM D-1002
Elcometer Adhesion to prepared cementitious surfaces primed with ENECLAD™CFS is greater than the cohesive strength of the substrate.

ENECLAD™CFS Technical Data

Theoretical coverage rate per kg. @ 3 mils.

125 ft2 / 11.6 m2

Mixing Ratio Base Activator
By Volume 2 1
By Weight 2.4 1

Ambient
Temperature
Pot Life Minimum
Overcoating
Maximum
Overcoating
41°F 5°C 2 hrs 12 hours 2 days
59°F 15°C 40 min 6 hrs 18 hrs
77°F 25°C 20 min 3 hrs 8 hrs
86°F 30°C 15 min 2 hrs 6 hrs

Chemical Resistance
Acetic acid (0-10%) G Methyl ethyl ketone NR
Acetic acid (10-20%) NR Naptha EX
Acetone NR Nitric acid (0-10%) G
Aviation fuel (JP-4) EX Nitric acid (10-20%) G
Butyl alcohol EX Phenol NR
Calcium chloride EX Phosphoric acid (0-10%) G
Carbon tetrachloride G Phosphoric acid (10-20%) G
Chloroform NR Potassium chloride EX
Crude oil EX Propyl alcohol EX
Diesel oil EX Skydrol G
Ethyl alcohol EX Sodium chloride EX
Gasoline EX Sodium hydroxide EX
Heptane EX Sulfuric acid (0-10%) EX
Hydrochloric acid (0-10%) EX Sulfuric acid (10-20%) EX
Hydrochloric acid (10-20%) EX Toluene NR
Kerosene EX Trichlorethylene NR
Methyl alcohol G Xylene G

EX - Suitable for most applications including immersion.
G - Suitable for intermittent contact, splashes, etc.
NR- Not recommended

Extended CHEMCLAD® SC Information:
CHEMCLAD® SC Product Info
CHEMCLAD® SC Instructions For Use - Easy step by step
CHEMCLAD® SC News pdf Newsletter briefs
CHEMCLAD® SC Literature Acrobat® pdf 211kb

Using CHEMCLAD® SC

Surface Preparation - CHEMCLAD® SC should only be applied to clean, firm, dry, and well roughened surfaces.

1.Remove all loose material and surface contamination.

2.Depending on the surface, solvent clean and / or remove contamination by abrasive blasting, steam cleaning, pressure washing, or other suitable means.

3.New concrete should be allowed to cure for a minimum of 28 days prior to treatment. Insure that all laitance is removed from cementitious surfaces before applying CHEMCLAD®

4.After removing all surface and subsurface contamination, flush the area as necessary and allow to dry completely.

5.Metallic surfaces which will be subject to immersion service should be abrasive blasted to achieve a "white metal" finish and a 3 mil profile.

Priming Concrete Surfaces - Prior to applying CHEMCLAD® SC to concrete and/or cementitious substrates, the surface should be treated with ENECLAD® CFS to seal the surface and insure optimum adhesion is obtained. After mixing, CFS should be applied using a brush or roller at the rate of 125 square feet (11 - 12 square meters) per kilogram to achieve the recommended film thickness of 3 mils. Please note: Coverage will be reduced on excessively rough and/or porous surfaces. The application of the CHEMCLAD® SC may commence as soon as the applied CFS is tacky and should be completed within 8 hours of priming. For specific details concerning the use of the CFS, please refer to the appropriate section of the ENECLAD® CFS Tech Sheet.

Mixing & Application - CHEMCLAD SC is supplied in pre - measured quantities to simplify mixing of full units. Simply pour the contents of the Activator container into the Base container; then, using a stirrer, or a paint mixer in an electric drill, mix thoroughly until a uniform, streak-free color is achieved. Apply the mixed CHEMCLAD® SC to the prepared (and/or primed) surface using a brush, squeegee or roller.

As a guide, a coverage rate of 50 - 55 square feet (5 square meters) per kilogram should result in an applied thickness of approximately 6 - 7 mils on a relative surface.

Please note : Shape contour, porosity, roughness, etc. will affect the coverage obtainable. Since a minimum of two coats are recommended, CHEMCLAD® SC is available in five colors, gray, haze gray, white, safety yellow and tan, to simplify overcoating.

Health and Safety - Every effort is made to insure that ENECON® products are as simple and safe to use as possible. Normal industry standards and practices for housekeeping, cleanliness and personal protection should be observed.

For further information and guidance, please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material and also available on request.

Cleaning of Equipment - Wipe excess material from tools immediately. Use acetone, MEK, Isopropyl alcohol similar solvent as needed.

Technical Support - The ENECON engineering team is always available to provide technical support and assistance. For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center.


All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.

Copyright © 2008 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.

 888-4-ENECON

About ENECONPrivacyTerms of UseEnecon ChinaEnecon en Español