| Technical Data |
 |
| Volume capacity per kg. |
48 in3 / 781 cc |
| Mixed density |
0.044 lbs per in3 /
1.28 gm per cc |
Coverage rate per kg.
@ 6-7 mils. |
50-55 ft2 / 5 m2 |
| Shelf life |
Indefinite |
| Volume solids |
100% |
| Mixing ratio |
Base |
Activator |
| By volume |
5.0 |
2 |
| By weight |
3.8 |
1 |
|

Cure Times |
 |
Ambient
Temperature |
Working
Life |
Touch
Dry |
Maximum
Overcoating |
Full
Cure |
| 41°F |
5°C |
110 min |
55 hrs |
96 hrs |
10 days |
| 59°F |
15°C |
90 min |
24 hrs |
48 hrs |
6 days |
| 77°F |
25°C |
70 min |
16 hrs |
24 hrs |
4 days |
| 86°F |
30°C |
55 min |
8 hrs |
16 hrs |
3 days |
|

Physical Properties |
 |
| |
Typical Values |
Test Method |
| Tensile Shear Adhesion |
| Steel |
3700 psi |
259 kg/cm2 |
ASTM D-1002 |
| Aluminum |
2700 psi |
189 kg/cm2 |
ASTM D-1002 |
| Copper |
3000 psi |
210 kg/cm2 |
ASTM D-1002 |
| Stainless steel |
3500 psi |
245 kg/cm2 |
ASTM D-1002 |
| Elcometer Adhesion to prepared cementitious surfaces primed with
ENECLAD™CFS is greater than the cohesive strength of the substrate. |
|

ENECLAD™CFS Technical Data |
 |
|
Theoretical coverage rate per kg. @ 3 mils. |
125 ft2 /
11.6
m2 |
|

|
| Mixing
Ratio |
Base |
Activator |
| By Volume |
2 |
1 |
| By Weight |
2.4 |
1 |
|

|
Ambient
Temperature |
Pot Life |
Minimum
Overcoating |
Maximum
Overcoating |
| 41°F |
5°C |
2 hrs |
12 hours |
2 days |
| 59°F |
15°C |
40 min |
6 hrs |
18 hrs |
| 77°F |
25°C |
20 min |
3 hrs |
8 hrs |
| 86°F |
30°C |
15 min |
2 hrs |
6 hrs |
|
|
 |
 |
|

|
|
Surface Preparation - CHEMCLAD® SC should only be applied to clean, firm, dry, and well roughened surfaces. |
 |
1.Remove all loose material and surface contamination.

2.Depending on the surface, solvent clean and / or remove contamination by abrasive blasting, steam cleaning, pressure washing, or other suitable means.

3.New concrete should be allowed to cure for a minimum of 28 days prior to treatment. Insure that all
laitance is removed from cementitious surfaces before applying CHEMCLAD®

4.After removing all surface and subsurface contamination, flush the area as necessary and allow to dry completely.

5.Metallic surfaces which will be subject to immersion service should be abrasive blasted to achieve a "white metal" finish and a 3 mil profile. |
Priming Concrete Surfaces - Prior to applying
CHEMCLAD® SC to concrete and/or cementitious
substrates, the surface should be treated with ENECLAD®
CFS to seal the surface and insure optimum adhesion is
obtained. After mixing, CFS should be applied using a brush
or roller at the rate of 125 square feet (11 - 12 square
meters) per kilogram to achieve the recommended film
thickness of 3 mils. Please note: Coverage will be reduced
on excessively rough and/or porous surfaces. The
application of the CHEMCLAD® SC may commence as
soon as the applied CFS is tacky and should be completed
within 8 hours of priming. For specific details concerning the
use of the CFS, please refer to the appropriate section of
the ENECLAD® CFS Tech Sheet.
Mixing & Application - CHEMCLAD SC is supplied in pre -
measured quantities to simplify mixing of full units. Simply
pour the contents of the Activator container into the Base
container; then, using a stirrer, or a paint mixer in an
electric drill, mix thoroughly until a uniform, streak-free
color is achieved. Apply the mixed CHEMCLAD® SC to the prepared
(and/or primed) surface using a brush, squeegee or roller.
As a guide, a coverage rate of 50 - 55 square feet (5 square
meters) per kilogram should result in an applied thickness of
approximately 6 - 7 mils on a relative surface.
Please note : Shape contour, porosity, roughness, etc. will affect
the coverage obtainable. Since a minimum of two coats are
recommended, CHEMCLAD® SC is available in five colors, gray,
haze gray, white, safety yellow and tan, to simplify overcoating.
Health and Safety - Every effort is made to insure that
ENECON® products are as simple and safe to use as possible.
Normal industry standards and practices for housekeeping,
cleanliness and personal protection should be observed.
For further information and guidance, please refer to the detailed
MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material
and also available on request.
Cleaning of Equipment - Wipe excess material from tools
immediately. Use acetone, MEK, Isopropyl alcohol similar solvent
as needed.
Technical Support - The ENECON engineering team is always
available to provide technical support and assistance. For
guidance on difficult application procedures or for answers to
simple questions, call your local ENECON® Fluid Flow Systems
Specialist or the ENECON® Engineering Center. |
|

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.
Copyright © 2008 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.
|
|