| Technical Data |
 |
| Volume capacity per 15 kg. |
400 in3 / 6580 cc |
| Mixed density |
0.082 lbs per in3 /
2.28 gm per cc |
Coverage rate per 15 kg.
@ 0.25 in / 6 mm |
12 ft2 / 1.1 m2 |
| Shelf life |
Indefinite |
| Volume solids |
100% |
| Mixing ratio |
Base |
Activator |
| By volume |
5.0 |
2 |
| By weight |
2.6 |
1 |
|

Cure Times |
 |
Ambient
Temperature |
Working
Life |
Light Load |
Full
Mechanical |
Chemical
Immersion |
| 41°F |
5°C |
3 hrs |
3 days |
7 days |
10 days |
| 59°F |
15°C |
90 min |
6 hrs |
36 hrs |
7 days |
| 77°F |
25°C |
60 min |
4 hrs |
24 hrs |
4 days |
| 86°F |
30°C |
30 min |
3 hrs |
16 hrs |
3 days |
|

Physical Properties |
 |
| |
Typical Values |
Test Method |
| Compressive Strength |
15,500 psi |
1085 kg/cm2 |
ASTM C-109 |
| Compressive modulus |
640,000 psi |
44,800 kg/cm2 |
ASTM C-109 |
| Compressive stress |
13,000 psi |
910 kg/cm2 |
ASTM C-109 |
| Flexural modulus |
310,000 psi |
21,700 kg/cm2 |
ASTM D-790 |
| Coefficient of Expansion |
3.5 x 10-6 in/°C |
ASTM D-696 |
| Izod impact strength |
0.5 ft lbs/in
|
0.27 j/cm
|
ASTM D-256 |
| Hardness - Shore D |
88
|
|
ASTM D-2240 |
|
Tensile shear adhesion -steel
|
1900 psi
|
133 kg/cm2
|
ASTM D-1002 |
 |
| Elcometer adhesion - to cementitious and mineral type substrates is generally greater than the cohesive strength of such materials. |
| Surface resistivity |
1 x 1015
ohms |
ASTM D-257 |
| Volume resistivity |
1 x 1015
ohm/cm |
ASTM D-257 |
| Electric strength |
210
volts / mil |
ASTM D-149 |
| Dielectric constant |
7.5 |
ASTM D-150 |
|
|
 |
 |
|

|
|
Surface Preparation - ENECRETE® DuraQuartz™ should only be applied to clean, dry, firm and well roughened surfaces. |
 |
1.Remove all loose material and surface contamination.

2.Depending on the surface, solvent clean and/or remove contamination by abrasive blasting, steam cleaning, pressure washing, or other suitable means.

3.After removing all surface and sub-surface contamination, flush the area as necessary and allow to dry completely.

4.Mix and apply DuraQuartz™ Primer in accordance with the Instruction Sheet supplied with the material. |
|
Note: In situations where adhesion is not desired, such as when making molds and patterns or to ease future disassembly, apply a suitable release agent (mold release compound, paste wax, etc.) to the appropriate surfaces.

Priming The Surface -
ENECRETE® Primer is supplied in each DuraQuartz™ system. Pour the contents of the Primer Activator container into the Primer Base container and mix thoroughly. Apply the mixed Primer to the area to be coated with DuraQuartz™ using a brush or a roller. Use only enough Primer to "wet" the surface; do not flood or pool the Primer. All the Primer should be used within 20 minutes of mixing. Overcoating with DuraQuartz™ should begin immediately after Priming and should be completed within two hours.

Mixing & Application - For your convenience, the
ENECRETE® DuraQuartz™ Base, Activator and Aggregate have been
supplied in precisely measured quantities to simplify mixing of
full units. Should a small amount of material be required,
measure out 5 parts Base and 2 parts Activator by volume ( 5:2,
v/v ) and add Aggregate until the desired consistency is
achieved.

To facilitate mixing of full units, a mechanical mixing device
is strongly recommended. Combine the Base and Activator liquids
in the large, plastic bucket and, with the mixer running, slowly
add the Aggregate. Using all the Aggregate will yield a stiff,
mortar-like paste; less Aggregate will result in a viscous fluid
consistency.

Apply the mixed DuraQuartz™ to the prepared and Primed surface
using a trowel, putty knife, or other appropriate tool, pressing
well to insure intimate contact and force out any air entrapped
as a result of the mixing technique and/or device used.

Top Coating DuraQuartz™ with one of the ENECON coatings should
be completed within 24 hours.

Health and Safety - Every effort is made to insure that ENECON® products are as simple and safe to use as possible. Normal industry standards and practices for housekeeping, cleanliness and personal protection should be observed.

Please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material (also available on request) for more information.

Cleaning Equipment - Wipe excess material from tools immediately. Use acetone,
MEK, isopropyl alcohol or similar solvent as needed.

Technical Support - The ENECON® engineering team is always available to provide technical support and assistance. For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center. |
|

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.

Copyright © 1998 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.
|
|