Technical Data
Volume capacity per kg. 33 in3 / 540 cc
Mixed density 0.065 lbs per in3 / 1.80 gm per cc
Coverage rate per kg.
3 mil/75 microns
150 ft2 / 14 m2
Shelf life Indefinite
Volume solids 100%
Mixing ratio Base Activator
By volume 2 1
By weight 2.4 1

Cure Times
Ambient
Temperature
Working
Life
Light Load Full
Mechanical
41°F 5°C 3 hrs 3 days 10 days
59°F 15°C 90 min 6 hrs 7 days
77°F 25°C 60 min 4 hrs 4 days
86°F 30°C 30 min 3 hrs 3 days

Physical Properties
  Typical Values

Test Method

Compressive strength 11,000 psi 770 kg/cm2 ASTM D-695
Flexural strength 4,000 psi 280 kg/cm2 ASTM D-790
Hardness-Shore D 88   ASTM D-2240
Tensile shear adhesion
Steel 2,000 psi 140 kg/cm2 ASTM D-1002
Adhesion - to prepared cementitous surfaces is greater than the cohesive strength of the substrate.

Chemical Resistance
Acetic acid (0-5%) G Methyl alcohol G
Acetone G Methyl ethyl ketone G
Ammonia solution (0-10%) EX Nitric acid (0-10%) G
Aviation fuel EX Palmitic acid EX
Butyl alcohol G Phosphoric acid (0-5%) EX
Calcium chloride EX Phosphoric acid (5-10%) G
Crude oil EX Potassium chloride EX
Diesel fuel EX Propyl alcohol G
Ethyl alcohol G Sodium chloride EX
Gasoline EX Sodium hydroxide EX
Heptane EX Sulfuric acid (0-50%) G
Hydrochloric acid (0-10%) EX Tannic acid EX
Hydrochloric acid (10-20%) G Toluene G
Kerosene EX Transformer oil EX
Lactic acid (0-10%) G Xylene EX

EX - Suitable for most applications including immersion.
G - Suitable for intermittent contact, splashes, etc.

Extended ENECLAD® SPS Information:
ENECLAD® SPS Product Info
ENECLAD® SPS Instructions For Use - Easy step by step
ENECLAD® SPS News pdf Newsletter briefs
ENECLAD® SPS Literature Acrobat® pdf 805kb
USING ENECLAD® SPS
Surface Preparation - ENECLAD SPS should only be applied to clean, dry, firm and well roughened surfaces.
1. Remove all loose material and surface contamination
2. Depending on the surface, solvent clean and/or remove contamination by abrasive blasting, steam cleaning, pressure washing, or other suitable means.
3. After removing all surface and sub-surface contamination, flush the area as necessary and allow to dry completely.

Mixing & Application - For your convenience, the ENECLAD® SPS Base, Activator and Aggregate have been supplied in precisely measured quantities to simplify mixing of full units. Should a small amount of material be required, measure out 2 parts Base and 1 part Activator by volume ( 2:1, v/v ) and then adding Aggregate to the desired consistency.

While hand mixing is possible, the use of a mechanical mixing device such as a paint mixer in an electric drill or other suitable device will accelerate the mixing process. Pour the entire contents of both the Base and Activator cans into the large plastic bucket and mix the liquids together. With the mixing device running, slowly add the Aggregate. Continue mixing until a smooth, uniform mixture is obtained.

Apply the mixed ENECLAD® SPS to the surface using an appropriate tool. While a trowel may be suitable for relatively small areas, the use of a long handled, rubber floor squeegee has been found most effective on larger areas. In either case, press the material in well to eliminate entrapped air and insure thorough contact with the surface.

Note: it may be necessary to mix the material repeatedly during the application process to insure uniform distribution of the Aggregate and prevent settling.

Health and Safety - Every effort is made to insure that ENECON® products are as simple and safe to use as possible. Normal industry standards and practices for housekeeping, cleanliness and personal protection should be observed. Please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material (also available on request) for more information.

Cleaning Equipment - Wipe excess material from tools immediately. Use acetone, MEK, isopropyl alcohol or similar solvent as needed.

Technical Support - The ENECON engineering team is always available to provide technical support and assistance. For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center.

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.

Copyright © 2008 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.

 1-888-4-ENECON

About ENECONPrivacyTerms of UseEnecon ChinaEnecon en Español