| Technical Data |
 |
| Volume capacity per kg. |
33 in3 / 540 cc |
| Mixed density |
0.065 lbs per in3
/ 1.80 gm per cc |
Coverage rate per kg.
3 mil/75 microns |
150 ft2 / 14 m2 |
| Shelf life |
Indefinite |
| Volume solids |
100% |
| Mixing ratio |
Base |
Activator |
| By volume |
2 |
1 |
| By weight |
2.4 |
1 |
|

Cure Times |
 |
Ambient
Temperature |
Working
Life |
Light Load |
Full
Mechanical |
| 41°F |
5°C |
3 hrs |
3 days |
10 days |
| 59°F |
15°C |
90 min |
6 hrs |
7 days |
| 77°F |
25°C |
60 min |
4 hrs |
4 days |
| 86°F |
30°C |
30 min |
3 hrs |
3 days |
|

Physical Properties |
 |
| |
Typical Values |
Test Method |
| Compressive strength |
11,000 psi |
770 kg/cm2 |
ASTM D-695 |
| Flexural strength |
4,000 psi |
280 kg/cm2 |
ASTM D-790 |
| Hardness-Shore D |
88 |
|
ASTM D-2240 |
| Tensile shear adhesion |
| Steel |
2,000 psi |
140 kg/cm2 |
ASTM D-1002 |
|
Adhesion - to prepared
cementitous surfaces is greater than the cohesive strength
of the substrate. |
|
|
 |
 |
 |
|
USING ENECLAD® SPS |
Surface Preparation - ENECLAD SPS should only be applied to
clean, dry, firm and well roughened surfaces.
1. Remove all loose material and surface contamination
2. Depending on the surface, solvent clean and/or remove
contamination by abrasive blasting, steam cleaning, pressure
washing, or other suitable means.
3. After removing all surface and sub-surface
contamination, flush the area as necessary and allow to dry
completely.

Mixing & Application - For your convenience, the
ENECLAD® SPS Base, Activator and Aggregate have been supplied in
precisely measured quantities to simplify mixing of full units.
Should a small amount of material be required, measure out 2
parts Base and 1 part Activator by volume ( 2:1, v/v ) and then
adding Aggregate to the desired consistency.

While hand mixing is possible, the use of a mechanical mixing
device such as a paint mixer in an electric drill or other
suitable device will accelerate the mixing process. Pour the
entire contents of both the Base and Activator cans into the
large plastic bucket and mix the liquids together. With the
mixing device running, slowly add the Aggregate. Continue mixing
until a smooth, uniform mixture is obtained.

Apply the mixed ENECLAD® SPS to the surface using an appropriate
tool. While a trowel may be suitable for relatively small areas,
the use of a long handled, rubber floor squeegee has been found
most effective on larger areas. In either case, press the
material in well to eliminate entrapped air and insure thorough
contact with the surface.

Note: it may be necessary to mix the material repeatedly during
the application process to insure uniform distribution of the
Aggregate and prevent settling.

Health and Safety - Every effort is made to insure that
ENECON® products are as simple and safe to use as possible.
Normal industry standards and practices for housekeeping,
cleanliness and personal protection should be observed. Please
refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS)
supplied with the material (also available on request) for more
information.

Cleaning Equipment - Wipe excess material from tools
immediately. Use acetone, MEK, isopropyl alcohol or similar
solvent as needed.

Technical Support - The ENECON engineering team is always
available to provide technical support and assistance. For
guidance on difficult application procedures or for answers to
simple questions, call your local ENECON® Fluid Flow Systems
Specialist or the ENECON® Engineering Center.
 |
|
All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.
Copyright © 2008 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation. |
|