| Technical Data |
 |
| Volume capacity per kg. |
565 cc / 35 in3 |
| Mixed density |
1.77 gm per cc or 0.064 lbs
/ in3 |
| Shelf life |
18 Months in unopened,
original containers |
| Working Time |
30 seconds |
| Final Set |
45 - 90 seconds |
| Mixing ratio |
Powder |
Water |
| By volume |
3.0 |
1.0 |
| By weight |
3.6 |
1.0 |
 |
| Compressive Strength (ASTM
C-109) |
|
1 Hour = 1000 psi |
|
1 Day = 3500 psi |
|
1 Month = 5000 psi |
|
|
 |
 |
|

|
|
Surface Preparation - Holes and cracks should be chiseled out to at least ¾ inches in depth and width, with the rear of the hole slightly larger than the opening. The chiseled opening should be cleaned to remove any loose material, oil, grease, dirt, mold, mildew or algae.
 |
|
ENECRETE® WP is designed to stop active water leaks. It will begin to harden in approximately 30 seconds — remember to have the surface prepared properly before you start to mix. Mix only a small amount of ENECRETE WP at one time — about the size of a baseball. |

Mixing - ENECRETE® WP should be mixed with a gloved hand, in a clean plastic container with clean water, for 30 seconds maximum. Since ENECRETE® WP must be applied in one minute, only mix small amounts of it at a time.

Application - After mixing, the ENECRETE WP is formed into
a ball and forced by hand or trowel into
the crack or hole. The mixed material should be held in place
for approximately 30 seconds until it hardens.

Cleaning Equipment - Wash gloves, mixing bucket and
utensils with water. Once hardened, remove by
mechanical methods.

Storage - Storage in a tightly sealed container at 50 °F
to 90°F in a clean, dry area.

Health & Safety - Every effort is made to insure that
ENECON® products are as simple and safe to use as
possible. Normal industry standards and practices for
housekeeping, cleanliness and personal protection should
be observed. Please refer to the detailed MATERIAL
SAFETY DATA SHEETS (MSDS) supplied with the material
(also available on request) for more information.

Technical Support - The ENECON engineering team is
always available to provide technical support and
assistance. For guidance on difficult application
procedures or for answers to simple questions, call your
local ENECON® Fluid Flow Systems Specialist or the
ENECON® Engineering Center. |
|

Every effort is made to insure that ENECON® products are as simple and safe to use as possible. Normal industry standards and practices for housekeeping, cleanliness and personal protection should be observed. Please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material (also available on request) for more information.
All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.

Copyright © 2008 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.
|
|