Search the site:

Homepage > Polymer Products > Weather/Water Proofing > Enecrete® WS

Technical Data
Volume capacity per 15 kg. .39 ft3
675 in3
11060 cc
Coverage per 15 kg. kit 65 - 75 ft2 @ 1/16"
depending on surface roughness
Shelf life 18 Months in unopened,
original containers.
Mixing ratio Powder Water
By volume 1.3 1.0
By weight 3.3 1.0
Extended ENECRETE® WS Information:

ENECRETE® WS Product Info

ENECRETE® WS Instructions For Use - Easy step by step
ENECRETE® WS News pdf Newsletter briefs
ENECRETE® WS Literature Acrobat® pdf 505kb

Using Enecrete® WS

Surface Preparation: ENECRETE® WS should only be applied to clean, damp, firm and roughened surfaces.

1. Remove all loose material and surface contamination, such as grease, oil, mold, algae and other coatings.

2. Depending on the surface, remove contamination by detergent and/or solvent washing, abrasive blasting, steam cleaning, pressure washing or other suitable methods.

3. After removing all surface and sub-surface contamination, flush the surface with clean water and allow surface water to dissipate.


Mixing - For your convenience, the ENECRETE® WS powder and liquid have been supplied in precisely measured quantities to simplify mixing. Remove the powder and liquid from the bucket, pour the liquid into the bucket and slowly add the powder to the liquid as you are mixing. To facilitate mixing of a full unit, a mechanical mixing device is recommended, such as a drill and a general purpose mixer blade.

Brushable consistency — add the entire gallon container of liquid to the bucket.

Trowelable consistency — add only enough liquid to obtain the desired consistency.


APPLICATION - ENECRETE® WS should be applied over a damp surface with no standing water present. Apply with a stiff, short bristle brush, such as a wallpaper paste brush. It should be applied in 2 coats, with each coat approximately 1/16 inch thick. The second coat should be applied perpendicular to the first coat. Recoat time at 75 °F is approximately 1-1/2 hours. Do not apply if the surface or air temperature is below 45°F.

Clean up - Clean all tools with water, immediately after use. Cured product must be mechanically removed.

Technical Support - The ENECON® engineering team is always available to provide technical support and assistance.

For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center.


Every effort is made to insure that ENECON® products are as simple and safe to use as possible. Normal industry standards and practices for housekeeping, cleanliness and personal protection should be observed. Please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material (also available on request) for more information.

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.

Copyright © 2001 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.

 1-888-4-ENECON

About ENECONPrivacyTerms of UseEnecon ChinaEnecon en Español