| Technical Data |
 |
| Unit size |
20 kg |
| Color |
Light gray |
| Finish |
Satin
(semi-gloss) |
| Volume Solids |
58% |
| Vehicle Type |
Water based elastomeric acrylic polymer. |
| Recommended Film Thickness |
12-14 mils
WFT per coat.
7-8 mils DFT per coat. |
| Coverage Rate |
Approx. 500 sq.
ft. per 20 kg unit per coat
@ 12 mils WFT based on a smooth substrate. Rough substrates
will reduce coverage. |
| Shelf Life |
3 years in
an unopened container.
Do not allow to freeze. |
| Overcoating |
4 hours minimum (16+ hours optimum) |
| Rain Resistant |
4 hours minimum (77° F / 25° C) |
| Elongation |
300% (ASTM D-2370) |
| Accelerated
Weathering |
1,000 hours
(12 hour cycle)
QUV Weather-O-Meter.
No changes in appearance. |
| Salt Fog
Resistance |
1,000 hours
(ASTM B-117)
No blistering.
No delamination. |
| Tape Adhesion |
5A (ASTM
D-3359 Method A)
Wire-brushed steel substrate. |
| Direct Tensile
Adhesion |
850 psi
(ASTM D-4541) Wire-brushed steel.
900 psi (ASTM D-4541) Galvanized steel. |
| Water Vapor
Transmission |
1.14g/h x m2 (ASTM E-96) |
| Spraying |
Airless
spray.
Recommended pressure: 2,500 to 3,000 psi.
Tip orifice: 0.013 to 0.019. |
|
 |
|
 |
 |
|
|
|
Surface Preparation - ENESEAL®CR
should only be applied to clean, dry and structurally sound
surfaces. Surfaces should be free of any loose material and all
contaminants such as dirt, oil, grease, salt, loose or flaking
paint, etc.

...for metal surfaces
While abrasive blasting is not necessary, all areas to be
treated should be manually prepared to SSPC SP-2 or SP-3 by
grinding, rotary wire brushing or other appropriate means to
remove loose rust, scale, or previously applied coatings.
Alternatively, high pressure water jetting in accordance with
SSPC SP-12 to a minimum visual condition of WJ-4 has been found
very effective on large areas to achieve the desired surface
prior to application.

...for cementitious surfaces
High pressure water jetting or light abrasive blasting have
generally been found to be the most effective means of removing
loose material and the typically weak surface layer often
encountered when preparing concrete/mineral substrates.

Mixing - ENESEAL®CR is a one component product
which should be stirred slowly prior to application in order to
blend in any slight separation.

Thinning of ENESEAL®CR with water or solvent is not
recommended.

Application - ENESEAL®CR should only be
applied when the temperature is above 45 F (7 ) and when the
relative humidity is below 85%. Surfaces being treated should be
at least 5 F (3 C) above the dew point.

ENESEAL®CR may be applied by brush, roller or spray.
The material should be applied at a wet film thickness of
approximately 12 - 14 mils (300 - 350 microns) to achieve the
desired dry film thickness of 7 - 8 mils (175 - 200 microns) per
coat. A minimum of two coats are recommended for most
applications.

Health & Safety - Every effort is made to insure that
ENECON® Products are as simple and safe to use as
possible. Normal industry standards and practices for
housekeeping, cleanliness and personal protection should be
observed. Please refer to the detailed MATERIAL SAFETY DATA
SHEET (MSDS) supplied with the material (also available on
request) for more information.

Cleaning Equipment - Wipe excess material from tools and
equipment immediately. Use soap and water as needed.

Technical Support - The ENECON® engineering team is always available to provide technical support and assistance.

For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center. |
|

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.

Copyright © 2008 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation. |
|