| Technical Data |
 |
Volume capacity per 167gm
"A Pack" |
4.3 in3 / 72 cc |
| Mixed density |
0.085 lbs per in3 /
2.33 gm per cc |
Coverage rate per kg.
@ 0.25 in / 6 mm |
17.2 in2 / 0.012 m2 |
| Shelf life |
Indefinite |
| Volume solids |
100% |
| Mixing ratio |
Base |
Activator |
| By volume |
1.0 |
1 |
| By weight |
2.0 |
1 |
|

Cure Times |
 |
Ambient
Temperature |
Working
Life |
Machining
Light Load |
Full
Mechanical |
Chemical
Immersion |
| 41°F |
5°C |
10 min |
60 min |
2 hrs |
72 hrs |
| 59°F |
15°C |
7 min |
45 min |
1 hrs |
48 hrs |
| 77°F |
25°C |
5 min |
30 min |
40 min |
36 hrs |
| 86°F |
30°C |
3 min |
20 min |
30 min |
24 hrs |
|

Physical Properties |
 |
| |
Typical Values |
Test Method |
| Compressive strength |
22,500 psi
|
1575 kg/cm2 |
ASTM D-695 |
| Flexural strength |
16,100 psi
|
1125 kg/cm2 |
ASTM D-790 |
| Izod impact strength |
1.3 ft lbs/in.
|
0.69 j/cm |
ASTM D-256 |
| Hardness - Rockwell |
R-90
|
|
ASTM D-785 |
| Hardness - Shore D |
84
|
|
ASTM D-2240 |
| Tensile Shear Adhesion |
| Steel |
2300 psi |
161 kg/cm2 |
ASTM D-1002 |
| Aluminum |
2100 psi |
147 kg/cm2 |
ASTM D-1002 |
| Copper |
2250 psi |
158 kg/cm2 |
ASTM D-1002 |
| Stainless Steel |
1800 psi
|
126 kg/cm2
|
ASTM D-1002 |
 |
| Surface resistivity |
1 x 1015
ohms |
ASTM D-257 |
| Volume resistivity |
1 x 1015
ohm/cm |
ASTM D-257 |
| Dielectric constant |
7.5 |
ASTM D-150 |
|
|
 |
 |
|
|
|
Surface Preparation - METALCLAD
SpeedAlloy™ should be applied only to clean, dry and well roughened surfaces. |
 |
1. Remove all loose material and surface contamination and clean with a suitable solvent which leaves no residue on the surface after evaporation such as acetone, MEK, isopropyl alcohol, etc.

2. If necessary, apply moderate heat to remove ingrained oil and clean again with solvent.

3. Roughen surface by abrasive blasting, grinding, rotary file or other appropriate means. |
|
Note: In situations where adhesion is not desired, such as when making molds and patterns or to ease future disassembly, apply a suitable release agent (mold release compound, paste wax, etc.) to the appropriate surfaces.
Mixing and Application -
For your convenience, the METALCLAD
SpeedAlloy™ Base and Activator have been supplied in precisely measured, convenient ‘A packs’ to simplify mixing.

To use this unique ‘A pack’, remove the divider and mix in the envelope until streak free. Then, cut one corner of the envelope and squeeze the mixed
SpeedAlloy™ out onto the repair area.

Using an appropriate tool, apply the mixed SpeedAlloy™ to the prepared surface, pressing firmly to insure intimate contact and eliminate any air pockets at the bond line or within the material.

In all cases, work quickly and deliberately, since SpeedAlloy™ is a fast system.

Some applications such as holed pipes or tanks and cracked casings may require the use of
ENECON® Reinforcement Tape to bridge the damaged area(s) followed by the application of additional material to completely cover the Reinforcement Tape.
Health and Safety - Every effort is made to insure that ENECON® products are as simple and safe to use as possible. Normal industry standards and practices for housekeeping, cleanliness and personal protection should be observed.

Please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material (also available on request) for more information.
Cleaning Equipment - Wipe excess material from tools immediately. Use acetone,
MEK, isopropyl alcohol or similar solvent as needed.
Technical Support - The ENECON® engineering team is always available to provide technical support and assistance. For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center. |
|

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.
Copyright © 1998 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.
|
|