Search the site:
Video GalleryPhoto Gallery

Homepage > Polymer Products > Weather/Water Proofing > SpeedAlloy™

Technical Data
Volume capacity per 167gm
"A Pack"
4.3 in3 / 72 cc
Mixed density 0.085 lbs per in3 / 2.33 gm per cc
Coverage rate per kg.
@ 0.25 in / 6 mm
17.2 in2 / 0.012 m2
Shelf life Indefinite
Volume solids 100%
Mixing ratio Base Activator
By volume 1.0 1
By weight 2.0 1

Cure Times
Ambient
Temperature
Working
Life
Machining
Light Load
Full
Mechanical
Chemical
Immersion
41°F 5°C 10 min 60 min 2 hrs 72 hrs
59°F 15°C 7 min 45 min 1 hrs 48 hrs
77°F 25°C 5 min 30 min 40 min 36 hrs
86°F 30°C 3 min 20 min 30 min 24 hrs

Physical Properties
  Typical Values

Test Method

Compressive strength 22,500 psi 1575 kg/cm2 ASTM D-695
Flexural strength 16,100 psi 1125 kg/cm2 ASTM D-790
Izod impact strength 1.3 ft lbs/in. 0.69 j/cm ASTM D-256
Hardness - Rockwell

R-90

  ASTM D-785
Hardness - Shore D

84

  ASTM D-2240
Tensile Shear Adhesion
Steel 2300 psi 161 kg/cm2 ASTM D-1002
Aluminum 2100 psi 147 kg/cm2 ASTM D-1002
Copper 2250 psi 158 kg/cm2 ASTM D-1002
Stainless Steel 1800 psi 126 kg/cm2 ASTM D-1002
Surface resistivity 1 x 1015 ohms ASTM D-257
Volume resistivity 1 x 1015 ohm/cm ASTM D-257
Dielectric constant 7.5 ASTM D-150

Chemical Resistance
Acetic acid (0-10%) EX Methyl alcohol G
Acetic acid (10-20%) G Methyl ethyl ketone G
Acetone G Nitric acid (0-10%) EX
Aviation fuel EX Nitric acid (10-20%) G
Butyl alcohol EX Phosphoric acid (0-5%) EX
Calcium chloride EX Phosphoric acid (5-10%) G
Crude oil EX Potassium chloride EX
Diesel fuel EX Propyl alcohol EX
Ethyl alcohol G Sodium chloride EX
Gasoline EX Sodium hydroxide EX
Heptane EX Sulfuric acid (0-10%) EX
Hydrochloric acid (0-10%) EX Sulfuric acid (10-20%) G
Hydrochloric acid (10-20%) G Toluene G
Kerosene EX Xylene EX

EX - Suitable for most applications including immersion.
G - Suitable for intermittent contact, splashes, etc.

Extended SpeedAlloy™ Information:
SpeedAlloy™ Product Info
SpeedAlloy™ Instructions For Use - Easy step by step
SpeedAlloy™ News pdf Newsletter briefs
SpeedAlloy™ Literature Acrobat® pdf 331kb

Using SpeedAlloy™

Surface Preparation - METALCLAD SpeedAlloy™ should be applied only to clean, dry and well roughened surfaces.

1. Remove all loose material and surface contamination and clean with a suitable solvent which leaves no residue on the surface after evaporation such as acetone, MEK, isopropyl alcohol, etc.

2. If necessary, apply moderate heat to remove ingrained oil and clean again with solvent.

3. Roughen surface by abrasive blasting, grinding, rotary file or other appropriate means.

Note: In situations where adhesion is not desired, such as when making molds and patterns or to ease future disassembly, apply a suitable release agent (mold release compound, paste wax, etc.) to the appropriate surfaces.

Mixing and Application -
For your convenience, the METALCLAD SpeedAlloy™ Base and Activator have been supplied in precisely measured, convenient ‘A packs’ to simplify mixing.

To use this unique ‘A pack’, remove the divider and mix in the envelope until streak free. Then, cut one corner of the envelope and squeeze the mixed SpeedAlloy™ out onto the repair area.

Using an appropriate tool, apply the mixed SpeedAlloy™ to the prepared surface, pressing firmly to insure intimate contact and eliminate any air pockets at the bond line or within the material.

In all cases, work quickly and deliberately, since SpeedAlloy™ is a fast system.

Some applications such as holed pipes or tanks and cracked casings may require the use of ENECON® Reinforcement Tape to bridge the damaged area(s) followed by the application of additional material to completely cover the Reinforcement Tape.

Health and Safety - Every effort is made to insure that ENECON® products are as simple and safe to use as possible. Normal industry standards and practices for housekeeping, cleanliness and personal protection should be observed.

Please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the material (also available on request) for more information.

Cleaning Equipment - Wipe excess material from tools immediately. Use acetone, MEK, isopropyl alcohol or similar solvent as needed.

Technical Support - The ENECON® engineering team is always available to provide technical support and assistance. For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center.


All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.

Copyright © 1998 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.

 888-4-ENECON

About ENECONPrivacyTerms of UseEnecon ChinaEnecon en Español