| Technical Data |
 |
| Volume capacity per 250gm
unit |
10.5 in3 / 172 cc |
| Mixed density |
0.052 lbs per in3 /
1.45 gm per cc |
Coverage rate per kg.
@ 0.25 in / 6 mm |
42 in2 / 0.027 m2 |
| Shelf life |
Indefinite |
| Volume solids |
100% |
| Mixing ratio |
Base |
Activator |
| By volume |
1.0 |
1 |
| By weight |
1.0 |
1 |
|

Cure Times |
 |
Ambient
Temperature |
Working
Life |
Light Load |
Full
Mechanical |
| 41°F |
5°C |
5 min |
30 min |
2 hrs |
| 59°F |
15°C |
2 min |
10 min |
1 hrs |
| 77°F |
25°C |
1 min |
5 min |
40 min |
| 86°F |
30°C |
45 sec |
3 min |
30 min |
|

Physical Properties |
 |
| |
Typical Values |
Test Method |
| Compressive strength |
11,000 psi
|
770 kg/cm2 |
ASTM D-695 |
| Hardness - Shore D |
80
|
|
ASTM D-2240 |
| Tensile Shear Adhesion |
| Steel |
2100 psi |
147 kg/cm2 |
ASTM D-1002 |
| Aluminum |
1900 psi |
133 kg/cm2 |
ASTM D-1002 |
| Copper |
1800 psi |
126 kg/cm2 |
ASTM D-1002 |
| Stainless Steel |
2000 psi
|
140 kg/cm2
|
ASTM D-1002 |
|
 |
 |
| SpeedAlloy™QS has an
extremely fast initial set up time, making it the ideal
material for stopping the flow and effectively plugging
virtually any leak. The use of the SpeedAlloy™QS, therefore,
provides time for proper surface preparation and application
of either standard SpeedAlloy™ or DurAlloy™ (over the
SpeedAlloy™QS) for a long-term repair. |
|
|
 |
 |
|
|
|
Surface Preparation - METALCLAD
SpeedAlloy™QS should be applied only to clean, dry and well
roughened surfaces for maximum adhesion. Under field condition,
perform the following steps as best as conditions permit. The
better the surface preparation, the better the adhesion. |
 |
1. Remove all loose material and surface contamination and clean with a suitable solvent which leaves no residue on the surface after evaporation such as acetone, MEK, isopropyl alcohol, etc.

2. If necessary, apply moderate heat to remove ingrained oil and clean again with solvent.

3. Roughen surface by abrasive blasting, grinding, rotary file or other appropriate means. |
|
Note: THIS IS AN EXTREMELY FAST SETTING
SYSTEM. SPEEDALLOY™QS MUST BE MIXED AND APPLIED WITHIN 1 MINUTE.

Mixing and Application -
For your convenience, the METALCLAD
SpeedAlloy™QS Base and Activator have been supplied in precisely
measured quantities to simplify mixing of full units. Should a
small amount of material be required, measure out one part Base
and one part Activator by volume (1:1 v:v) on a clean mixing
surface. Keep Base and Activator separated until ready to mix and
apply.

Using a spatula, putty knife or other appropriate tool, mix
thoroughly until all streaks disappear, resulting in a uniform
color and consistency. Apply to the area to be plugged or repaired
as quickly as possible (within 1 minute). Once the leak is
stopped, a long-term repair can be made using standard SpeedAlloy™
or DurAlloy™ over the SpeedAlloy™ QS.

Health and Safety - Every effort is made to insure that
ENECON® products are as simple and safe to use as possible. Normal
industry standards and practices for housekeeping, cleanliness and
personal protection.

Cleaning Equipment - Wipe excess material from tools
immediately. Use acetone, MEK, isopropyl alcohol or similar
solvent as needed.

Technical Support - The ENECON engineering team is always available to provide technical support and assistance. For guidance on difficult application procedures or for answers to simple questions, call your local ENECON Fluid Flow Systems Specialist or the ENECON Engineering Center. |
|

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.
Copyright © 1998 by ENECON Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON Corporation.
|
|