| Technical Data |
 |
| Volume capacity per kg. |
55 in3 / 900 cc |
| Mixed density |
0.040 lbs per in3 /
1.11 gm per cc |
Coverage rate per kg.
3 mil/75 microns |
125 ft2 / 11.6 m2 |
| Shelf life |
Indefinite |
| Volume solids |
100% |
| Mixing ratio |
Base |
Activator |
| By volume |
2 |
1 |
| By weight |
2.4 |
1 |
|

Cure Times |
 |
Ambient
Temperature |
Working
Life |
Light Load |
Full
Mechanical |
| 41°F |
5°C |
2 hrs |
3 days |
7 days |
| 59°F |
15°C |
40 min |
10 hrs |
36 hrs |
| 77°F |
25°C |
20 min |
5 hrs |
24 hrs |
| 86°F |
30°C |
15 min |
3 hrs |
16 hrs |
|

Physical Properties |
 |
| |
Typical Values |
Test Method |
| Compressive strength |
14,000 psi |
980 kg/cm2 |
ASTM D-695 |
| Flexural strength |
9,500 psi |
665 kg/cm2 |
ASTM D-790 |
| Hardness-Shore D |
80 |
|
ASTM D-2240 |
| Tensile shear adhesion |
| Steel |
3,000 psi |
210 kg/cm2 |
ASTM D-1002 |
|
Adhesion - to prepared
cementitous surfaces is greater than the cohesive strength
of the substrate. |
|
|
 |
 |
 |
|
USING ENECLAD® CFS |
Surface Preparation - ENECLAD® CFS should only be applied to clean, firm, dry and
well roughened surfaces.
1. Remove all loose material and surface and sub-surface
contamination.
2. Depending on the surface, solvent clean and/or remove
contamination by abrasive blasting, steam cleaning,
pressure washing, or other suitable means.
3. After removing all surface and sub-surface contamination,
flush the area as necessary and allow to dry completely.

Mixing & Application - For your convenience, the
ENECLAD® CFS Base and Activator have been supplied in precisely
measured quantities to simplify mixing of full units. Should
less than a full unit quantity of material be required for a
particular application, a partial mix can be accomplished by
mixing 2 parts Base to 1 part Activator by volume (2:1, v/v).

While hand mixing is possible, the use of a mechanical mixing
device such as a paint mixer in an electric drill or other
suitable device will accelerate the mixing process. Pour the
entire contents of the Activator container into the Base
container and mix the liquids together thoroughly. Once mixed,
the unit should be poured into smaller containers and / or
roller pans to prolong its working life.

Apply the mixed ENECLAD® CFS to the surface using brushes and /
or rollers. For large floor areas, long handled roller sets
should be used to ease the application. Regardless of the
application device / method, press the material in well to
eliminate entrapped air and insure thorough contact with the
surface.

Health and Safety - Every effort is made to insure that
ENECON® products are as simple and safe to use as possible.
Normal industry standards and practices for housekeeping,
cleanliness and personal protection should be observed. Please
refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS)
supplied with the material (also available on request) for more
information.

Cleaning Equipment - Wipe excess material from tools
immediately. Use acetone, MEK, isopropyl alcohol or similar
solvent as needed.

Technical Support - The ENECON® engineering team is
always available to provide technical support and
assistance. For guidance on difficult application procedures
or for answers to simple questions, call your local
ENECON® Fluid Flow Systems Specialist or the ENECON®
Engineering Center.
 |
|
All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.
Copyright © 2008 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation. |
|