| Technical Data |
 |
| Coverage rate per kg. @ 5
mils. |
40 - 45 ft2 / 4 m2 |
| Mixing ratio |
Base |
Activator |
| By volume |
5 |
1 |
| By weight |
10 |
1 |
|

Physical Properties |
 |
(ASTM D- 4541)
Direct Tensile
Adhesion to: |
Bond
Strength (psi) |
Failure Mode |
| *Unblasted Carbon
Steel |
1500 |
Stud and panel
adhesive failure |
| *Unblasted
Stainless Steel |
1400 |
Stud and panel
adhesive failure |
| *Unblasted
Galvanized Steel |
800 |
Panel adhesive
failure |
| *Smooth Plate
Glass |
1500 |
Glass cohesive
failure |
| *Unblasted
Aluminum |
1400 |
Stud and panel
adhesive failure |
| *Cured Epoxy
Coating |
1000 |
Stud, coating and
panel adhesive failure |
| *Glazed Ceramic
Tile |
700 |
Tile cohesive
failure |
| Dry Concrete |
400 |
Concrete cohesive
failure |
| Damp Concrete |
400 |
Concrete cohesive
failure |
| *Vinyl Tile |
500 |
Vinyl tile
cohesive failure |
| *Wood |
800 |
Wood cohesive
failure |
| *Substrates were
prepared with only an acetone wipe. |
|
|
 |
 |
|

|
|
Using SuperBond |
|
Surface Preparation - ENECLAD® SuperBond should only be
applied to clean surfaces. |
 |
1.Remove all loose material and surface contamination.

2.Clean the substrate with a suitable solvent that leaves no
residue on the surface after evaporation such as MEK, acetone,
denatured alcohol or isopropyl alcohol.

3.If necessary, apply moderate heat and/or allow ingrained
contaminants to leach out before the final solvent cleaning.

Note: Although surface roughening is not required for normal
applications, roughening of the surface will increase the
adhesion of ENECLAD® SuperBond, which may be desirable for
certain applications. |

Mixing - The individual components of this product should
be thoroughly stirred before the two are mixed together. Pour
the container of Activator into the Base container. Mix the two
components together either manually or mechanically. Blend the
material for 1 - 2 minutes. Stop and scrape the container sides
and bottom to incorporate any unmixed base or activator.
Continue mixing for 2-3 additional minutes.

Application - Apply by stiff brush or short nap roller.
ENECLAD® SuperBond should be applied at a minimum of 5 mils
thick, although rougher substrates will require thicker
applications. Stipple the SuperBond into any pits and cavities
as necessary.

The ENECLAD® SuperBond must be applied within its working time
and must be overcoated while tacky, within its maximum overcoat
time as follows:
 |
| Temperatures |
50°F |
59°F |
77°F |
86°F |
| 10°C |
15°C |
25°C |
30°C |
| Pot Life |
4 hr |
90 min. |
45 min. |
25 min. |
| Overcoat within |
24 hr. |
14 hr. |
8 hr. |
4 hr. |
| Full Cure |
10 Days |
7 Days |
4 Days |
3 Days |
|

Health & Safety - Every effort is made to ensure that
ENECON® products are as simple and safe to use as possible.
Normal industry standards and practices for housekeeping,
cleanliness and personal protection should be observed.

Please refer to the detailed MATERIAL SAFETY DATA SHEETS (MSDS)
supplied with the material (also available on request) for more
information.

Technical Support - The ENECON® engineering team is always available to provide technical support and assistance. For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center. |
|

All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained.
Copyright © 2007 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation.
|
|