| Technical Data |
 |
| Unit size |
15 liters |
| Color |
White |
| Finish |
Eggshell (flat) |
| Volume Solids |
56% |
| Vehicle Type |
Water based vinyl terpolymer matrix |
| Shelf Life |
2 years (some settling may occur - mix before use). Store between
41°F / 5°C and 95°F / 35°C |
| Drying Time |
Typically 1 hour under normal ambients conditions. Allow 24 hours before placing
components/equipment back in service. Full chemical cure 21 days. |
| Overcoating |
Additional
coat(s) may be applied after 2 hours under normal ambient conditions. |
| Coverage Rate |
35 - 40 ft² (3.3 - 3.7 m²) per liter per coat. Coverage rates will vary depending on the type of substrate, surface porosity, texture, etc. |
| Application Thickness |
6 mils dry film thickness
(DFT) per coat... two coats recommended. |
| Primer |
ENESEAL® CR
(for unpainted ferrous metals) |
| Thinning |
Use warm water (do not exceed 5% of
total volume). |
| Spraying |
Airless spray
equipment producing at least 4 liters/minute (1 gallon/minute).
Abrasion resistant tips...sizes .031 in. / .787 mm or 0.37
in. / .94 mm. |
|
 |
|
 |
 |
|
|
Surface Preparation - ENESEAL® HR should only be applied to
clean, dry and structurally sound surfaces. Concrete, brick,
block or other masonry or cementitious surfaces must be free of
efflorescence. Any contaminants, such as oil, must be removed by
pressure washing, steam cleaning, solvent cleaning, etc. Any
existing coatings must be sound and well bonded to the
substrate. Loose or flaking coatings must be removed by rotary
wire brushing, abrasive blasting, grinding or other suitable
means. All rust must be removed.
Priming Unpainted Ferrous Metal Surfaces - Prior to
applying ENESEAL® HR to unpainted ferrous metal surfaces, these
areas should be first primed with CHEMCLAD® SC to prevent rust
bleed through the water-based ENESEAL® HR. CHEMCLAD® SC is a two
-component 100% solids (solvent free) system. After thoroughly
mixing the Base & Activator, apply CHEMCLAD® SC by brush or
roller to cover all exposed (unpainted) ferrous metal surfaces
to which ENESEAL® HR will ultimately be applied. The working
life of the mixed CHEMCLAD® SC is 70 minutes at 77°F/25°C. One
coat of CHEMCLAD® SC is usually adequate. A typical coverage
rate of 50 - 55 ft2 (5m2) per kg. @ 6 - 7mils is recommended.
Please note: coverage will be reduced on excessively rough
and/or pitted surfaces. ENESEAL® HR may be applied over the
CHEMCLAD® SC when the CHEMCLAD® SC is tack-free, usually within
12 hours at about 77°F/25°C. If two coats of CHEMCLAD® SC are to
be applied, the maximum overcoating time for the second coat is
24 hours at 77°F/25°C. When mixing less than full units of
CHEMCLAD® SC, the mixing ratio by volume is 5 parts Base to 2
parts Activator; by weight the mixing ratio is 3.8 parts Base to
1 part Activator. CHEMCLAD® SC has an indefinite shelf life.
Application - ENESEAL HR is a water based system and,
therefore, must not be applied when freezing conditions exist or
are expected within 24 hours of the application. Do not apply
ENESEAL® HR if rain or snow is expected within 24 hours of the
application. Applications onto hot surfaces, i.e., steam pipes
or ducts, must not exceed 140° F/60°C. Equipment should first be
cooled prior to the application of the ENESEAL® HR. Once the
ENESEAL® HR has cured for 24 hours it can withstand dry heat
temperatures of up to 395°C F/200° C.
Applications to newly tarred or to petroleum based
materials/substrates must not be carried out until the material
has fully cured - - usually 2-3 months. New concrete must be
allowed to cure for at least 21 days before treating with the
ENESEAL® HR system.
Health & Safety - Every effort is made to insure that
ENECON® products are as simple and safe to use as possible.
Normal industry standards and practices for housekeeping,
cleanliness and personal protection should be observed.

For further information and guidance, please refer to the
detailed MATERIAL SAFETY DATA SHEETS (MSDS) supplied with the
material and also available on request.
Cleaning of Equipment - Wipe excess material from tools
and equipment immediately. Use soap and water as
needed.
Technical Support - The ENECON® engineering team is always available to provide technical support and assistance.
For guidance on difficult application procedures or for answers to simple questions, call your local ENECON® Fluid Flow Systems Specialist or the ENECON® Engineering Center. |
|
All information contained herein is based on long-term testing in our laboratories as well as practical field experience and is believed to be reliable and accurate. No condition or warranty is given covering the results from use of our products in any particular case, whether the purpose is disclosed or not, and we cannot accept liability if the desired results are not obtained....

Copyright © 2007 by ENECON® Corporation. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical including photocopying, recording, taping or information storage and retrieval systems - without written permission of ENECON® Corporation. |
|